FLN36-40.5D SF6 36KV LBS 350MM

    FLN36-40.5D SF6 36KV LBS 350MM

    FLN36-40.5D SF6 load circuit breaker 36KV LBS spacing 350MM FLRN36-40.5D indoor AC high-voltage sulfur hexafluoride load circuit breakers, load switch-fuse combination appliances and cable-mounted load switches are designed and developed by our company by absorbing foreign advanced technologies and combining with my country’s operating requirements. The product has been fully type tested and its performance meets the requirements of GB3804 “3~63kV AC high-voltage load switch”
  • делиться:
  • контакт Онлайн-запрос
  • почтовый ящик:ansel@apexe.cc

FLN36-40.5D SF6 load circuit breaker 36KV LBS spacing 350MM


1.FLRN36-40.5D indoor AC high-voltage sulfur hexafluoride load circuit breakers, load switch-fuse combination appliances and cable-mounted load switches are designed and developed by our company by absorbing foreign advanced technologies and combining with my country’s operating requirements. The product has been fully type tested and its performance meets the requirements of GB3804 “3~63kV AC high-voltage load switch”


2.GB16926 “High-voltage load switch-fuse combination appliances”, IEC60265, IEC60420 standards. The product has a “close-open-ground” three-position arc extinguishing chamber, reliable interlocking, high insulation strength of the break, large creepage distance design, and the outlet is protected by a voltage-equalizing protection cover. The cable-mounted load switch has a touchable cable front connector at the outlet, and high-voltage cables are installed on the incoming and outgoing lines, and is used in the cable branch (connection) box. The switch has a special dynamic seal and fixed seal design, which ensures reliable sealing. A pressure gauge is installed in a prominent position for monitoring during operation to ensure safe operation. It is a new generation of high-voltage Switchgear equipped for urban power grids.


Operating environment


●Altitude: The maximum altitude of the equipment installation site is 1000m;

●Ambient air temperature: upper limit +40C, lower limit -15C;

●Ambient humidity: daily average relative humidity is not more than 95%, monthly average relative humidity is not more than 90%;

Earthquake: earthquake intensity does not exceed 8 degrees;

●Ambient air should not be obviously polluted by corrosive and flammable gases, water vapor, etc., and there should be no frequent severe vibrations.


Technical Specification


No.ItemUnitParameter
1Rated voltageKV40.5
2Rated frequencyHz50
3Rated currentA630
41min Power frequency
withstand voltage
wetKV95
dry95
5Lightning impulse withstand voltageKV185
6Rated short circuit breaking
current(peak)
KA20
7Rated activeload and close circuit
breaking current
A630
8Rated transferring currentA630
9Rated short circuit making
current(peak)
KA63
10Rated cable(line)charging
breaking current
A10
11Cable charage breaking current
in earthing fault
A30
12Rated withstand current (peak)KA63
13Short time withsatnd current(2s)KA25
14Mechanism lifetime5000




Связанные теги:

Онлайн-сообщение

Пожалуйста, введите действительный адрес электронной почты.
код проверки Не может быть пустым

Связанные продукты

Нет результатов поиска!

Contact Information

Indiana Office

995 Green Hill St. Greenfield, IN 46140

1-800-1234-567

mail@demolink.org

New York Office

995 Green Hill St. Greenfield, IN 46140

1-800-1234-567

mail@demolink.org

Search

Этот веб-сайт использует файлы cookie, чтобы обеспечить вам максимально эффективное использование нашего веб-сайта.

Принимать отклонять